High-Voltage Diesel Generator Set-Getewell

News Center > Model Classification > High-Voltage Diesel Generator Set-Getewell

High-Voltage Diesel Generator Set-Getewell

Our company specializes in: 3-3000KW land-based diesel generator sets and gas generator sets; 15-600KW mobile trailer-mounted power stations; 12-1000KW marine diesel generator sets; various silent, mobile, medium-high voltage, multi-unit parallel, and gas-fired special generator sets; and imported series diesel generator sets and gas generator sets.

    

      With the expansion of the computer room, the capacity requirements for the diesel generator sets as backup power sources are increasing. Multiple high-power diesel generator sets need to be connected in parallel to meet the load requirements. Moreover, the distance between the computer room and the actual load is getting farther and farther. The traditional parallel operation of multiple low-voltage diesel generator sets exposes many operational and transmission defects. To ensure safer and more reliable operation, using high-voltage generator sets is a better choice. 


The high-voltage units are applied in emergency backup power systems of metallurgical enterprises, airports, data centers, etc. As the output voltage of the units is 10kV, which is consistent with the original power supply system voltage, they can be directly connected to the power supply system, eliminating the need for a large amount of equipment investment in the power distribution system. At the same time, due to the high output voltage and small output current of the units, there is little power loss during the power transmission process, making them suitable for long-distance transmission. 


The high-voltage power generation units produced by our company are applied in emergency backup power systems of metallurgical enterprises, airports, data centers, etc. As the output voltage of these units is 10kV, which is consistent with the original power supply system voltage, they can be directly connected to the power supply system, eliminating the need for a large investment in power distribution equipment. At the same time, due to the high output voltage and small output current of the units, there is less power loss during the power transmission process, making them suitable for long-distance transmission.




产品特点 二、高压柴油发电机组与低压柴油发电机组分析比较

特点

低压机组

高压机组

1

容量

可多台机组并联运行。

可多台机组并联运行,机房可集中建设。

2

输送距离

可短距离输电

可长距离输电,

3

损耗

在输配电中线路损耗较大

在输配电中线路损耗较小,不存在输送发热问题

4

成本

设备初期投资较少,维护成本较低,低容量、短距离具有较大优势,高容量、长距离使用时成本将远远高于高压机组

设备初期投资较大,维护成本较低,对于大容量、长距离输配电具有明显优势,配套投资费用较低

5

操作维护

操作使用较为简单,对操作使用人员要求较低。

操作使用较为复杂,操作使用人员要求较高,必须具有相应高压操作证才能操作。

6

配置

配置较为简单

配置较为复杂,尤其在发电机及输出配电柜方面。

7

安全

安全性能较高,技术较为成熟,技术门槛较低

安全性能较高,技术较为成熟,技术门槛较高。

8

发展趋势

小功率段保持传统市场,大功率段有被高压系统替代的势

采用高压系统为现时世界趋势,需求逐渐增大。

III. Relationship between Power, Voltage, and Current

P = 1.732 × U × I × COSΦ

Take a 2000kW unit as an example. With a power factor of 0.8 and a frequency of 50Hz, the low-voltage (400V) current is: I = P / (1.732 × U × COSΦ) = 2000 × 10³ / (1.732 × 400 × 0.8) = 3609A

The high-voltage (10.5KV) current is: I = P / (1.732 × U × COSΦ) = 2000 × 10³ / (1.732 × 10.5 × 10³ × 0.8) = 137A. The high-voltage transmission current is approximately 1/26 of the low-voltage transmission current.

IV. Application of High-Voltage Diesel Generator Sets

Based on the application characteristics of the high and low voltage diesel generator sets mentioned above, in applications with large capacity requirements and long transmission distances, high-voltage diesel generator sets have obvious advantages such as large capacity, long-distance power supply, centralized construction of the machine room, strong reliability, and simple supporting power distribution system. They are an inevitable trend for the selection and application of large-capacity units. High-voltage diesel generator sets have been widely applied in banks, data centers, metallurgy, aviation, and other fields.

The main voltage levels of 50Hz high-voltage diesel generator sets are: 6kV, 6.3kV, 6.6kV, 10kV, 10.5kV, 11kV, etc. Each unit has a power of generally over 1000kW, and multiple units are used in parallel.

V. Structural Characteristics of High-Voltage Diesel Generator Sets


设备名称

使用要求说明

备注

1

发动机

一般要求单台机组功率在1000KW以上,可选用康明斯、MTU等发动机

与低压机组没区别

2

发电机

可短距离输电

与低压发电机有较大区别,

3

连接方式

按不同电压等级选用,可选用STAMFORD、康富等品牌发电机

减震垫安装在底座下面

4

并机控制系统

双轴承发电机联轴器联接,工作可靠、安全性更高。

与低压并机控制系统没明显区 别,增加差动保护

5

高压开关柜

一般包括主控制器、同期装置等,可选用COMAP主控制系统、CUMMINSCATMTU并机控制系统、差动保护


6

PT

一般并机输出开关采用抽出式电动真空断路器、综保系统、直流操作。


VI. Brief Description of the Control System and Integrated Protection System

The high-voltage unit control system mainly consists of two parts: the high-voltage switch cabinet and the centralized control console.

The high-voltage switch cabinet can be centrally managed in a dedicated power distribution room, and the centralized control console can be installed in the central control room.

The integrated protectors installed on the high-voltage switch cabinet and the 8808 control panel on the centralized control console all have universal RS232 and MODBUS communication protocol interfaces. Users can collect real-time data of the entire control system as needed for centralized monitoring and archiving management. The high-voltage 8808 intelligent control system mainly consists of the generator incoming cabinet (parallel cabinet) and PT cabinet, and outgoing cabinet. The 8808 intelligent main controller itself has integrated comprehensive generator protection functions and has met the basic protection requirements of the unit and its affiliated equipment. As a backup redundant protection, users can select the integrated protection device (optional) and differential protection device (optional) on the parallel cabinet according to the actual project needs and operational habits, and the integrated protection device (optional) on the outgoing cabinet to effectively protect the unit and ensure stable operation of the equipment installation.

1. The above technical parameters are for 50Hz, rated voltage 400/230V, power factor 0.8, and connection method 3-phase 4-wire. 60Hz generator can be customized according to the customer's special needs.

2. The generator can be selected from well-known brands such as Kajelie, Stanford, Lilesenma, and Marathon according to the customer's needs.

3. This data sheet is for reference only. Any changes will not be notified separately.




安装示意图及参考尺寸

型号

混凝土基础平面(mm2

机房总面积(mm2

机房小高度(mm

V-68GF

2500×1000

4400×3300

3000

V-80GF

2500×1000

2500×1000

3000

V-104GF

2700×1000

4600×3300

3000

V-120GF

2700×1000

4700×3300

3000

V-140GF

3000×1200

4900×3300

3000

V-160GF

3500×1200

5000×3300

3000

V-200GF

3500×1500

5000×3300

3000

V-260GF V-300GF   V-320GF

4000×1500

6000×3300

3000

V-360GF V-400GF

4000×1500

6000×3300

3000

 

国产机组机房参考尺寸

型号

机房小高度(mm

备注

单台40-200KW6缸机机房

5000×3600×3200

135系列

240-200KW6缸机机房

6000×5000×3500

135系列

单台200-400KW12缸机机房

6000×5000×3200

135系列

2200-400KW12缸机机房

8000×6000×3500

135系列

单台(闭式)500-600KW机房

10000×7000×5000

8V190

单台(开式)500-600KW机房

9000×7000×5000

8V190

单台(闭式)700-1000KW机房

11000×8000×5500

12V190

单台(开式)700-1000KW机房

9000×8000×5500

12V190

Operating Instructions for Diesel Generators

1. Use No. 0 to -30# light diesel oil; specify to use 15W-40CD grade engine oil (or as required by the diesel engine manual).

2. The starting temperature should be above +5℃; when using an oil heating device with water, the starting temperature should be -15℃; when the unit is used below 0℃, anti-freezing fluid and other low-temperature starting measures should be adopted.

3. Noise coefficient of the unit: ≤ 85~95db(A), in line with international standards.

4. Our company can provide both land-based 8KW-1600KW units and ship-based units with the same power range, as well as various 60Hz 1800 rpm generators.

5. The generators produced by our company comply with the provisions of GB/T2820.1, 5, 6 and ISO8528 "Generators Driven by Reciprocating Internal Combustion Engines".

6. Adjustment method: automatic or manual.

7. Users in cold regions should note: according to the changes in temperature, the engine oil, diesel, and coolant should be appropriately adjusted to ensure the normal operation of the unit.

8. With the continuous update of products, if there are any changes or modifications in the sample parameters, they shall be subject to the random documents. Our company reserves the final interpretation right and will not issue separate notifications.