Container-type diesel generator sets come in standard and silent versions.
According to international standard container design and manufacturing, 1000KVA and below use 20-foot containers, while 1250KVA and above use 40-foot containers. It has a certificate of compliance with the international container safety convention CSC, and the entire unit can be directly transported by standard containers, significantly reducing transportation costs. The container is equipped with two explosion-proof lights / a single explosion-proof light on the control panel, facilitating user operation and maintenance. The container can be opened at both the front and rear, and there are side doors on both sides of the container, facilitating user maintenance and repair. A ladder is provided outside the container. All hinges, locks, and bolts are made of stainless steel. The container is equipped with anti-wave and anti-rain invasion devices. The control panel and output switch cabinet are on the same side of the container, facilitating user daily operation and output cable connection. The standard configuration includes a permanent magnet excitation PMG system, improving the motor's starting ability and having anti-interference capability against waveform distortion. The fuel tank and pipelines, oil discharge, muffler, etc. have many unique designs, highly favored by users.
The interior of the silent type container not only has high-performance, aged-resistant, flame-retardant sound insulation materials and sound absorption materials, but also has an excellent design for noise reduction in air intake and exhaust.
Product Features
The four sides of the container and the floor are covered with sound-absorbing cotton and metal perforated plates.
2. Anti-slip patterned aluminum plates are laid on the floor inside the box;
3. The noise reduction effect is 70 - 80 dBA (at 7 meters).
4. The box is equipped with a control room, an oil supply system, a lighting system, and there is also space reserved for maintenance.


型号 | 混凝土基础平面(mm2) | 机房总面积(mm2) | 机房小高度(mm) |
V-68GF | 2500×1000 | 4400×3300 | 3000 |
V-80GF | 2500×1000 | 2500×1000 | 3000 |
V-104GF | 2700×1000 | 4600×3300 | 3000 |
V-120GF | 2700×1000 | 4700×3300 | 3000 |
V-140GF | 3000×1200 | 4900×3300 | 3000 |
V-160GF | 3500×1200 | 5000×3300 | 3000 |
V-200GF | 3500×1500 | 5000×3300 | 3000 |
V-260GF V-300GF V-320GF | 4000×1500 | 6000×3300 | 3000 |
V-360GF V-400GF | 4000×1500 | 6000×3300 | 3000 |
国产机组机房参考尺寸
型号 | 机房小高度(mm) | 备注 |
单台40-200KW6缸机机房 | 5000×3600×3200 | 135系列 |
2台40-200KW6缸机机房 | 6000×5000×3500 | 135系列 |
单台200-400KW12缸机机房 | 6000×5000×3200 | 135系列 |
2台200-400KW12缸机机房 | 8000×6000×3500 | 135系列 |
单台(闭式)500-600KW机房 | 10000×7000×5000 | 8V190 |
单台(开式)500-600KW机房 | 9000×7000×5000 | 8V190 |
单台(闭式)700-1000KW机房 | 11000×8000×5500 | 12V190 |
单台(开式)700-1000KW机房 | 9000×8000×5500 | 12V190 |
Operating Instructions for Diesel Generators
1. Use No. 0 to -30# light diesel oil; specify to use 15W-40CD grade engine oil (or as required by the diesel engine manual).
2. The starting temperature should be above +5℃; when using an oil heating device with water, the starting temperature should be -15℃; when the unit is used below 0℃, anti-freezing fluid and other low-temperature starting measures should be adopted.
3. Noise coefficient of the unit: ≤ 85~95db(A), in line with international standards.
4. Our company can provide both land-based 8KW-1600KW units and ship-based units with the same power range, as well as various 60Hz 1800 rpm generators.
5. The generators produced by our company comply with the provisions of GB/T2820.1, 5, 6 and ISO8528 "Generators Driven by Reciprocating Internal Combustion Engines".
6. Adjustment method: automatic or manual.
7. Users in cold regions should note: according to the changes in temperature, appropriate adjustments should be made to the engine oil, diesel, and coolant to ensure the normal operation of the unit.
8. With the continuous update of products, if there are any changes or modifications in the sample parameters, they shall be subject to the random documents. Our company reserves the final interpretation right and will not issue a separate notice.